NVMe Persistent Event Log: Retrieval, Event Formats, and Historical Interpretation

29 minute read

繁體中文

00.01.After a device resets, how can we tell what happened before it? Persistent Event Log retains significant events in a common format, including health snapshots, firmware updates, power events, namespace changes and configuration. This report first explains consistent retrieval, then connects time, target, parameters and outcomes while respecting what the evidence can establish.

Persistent Event Log
The LID 0Dh history of significant subsystem events.
namespace
Namespace, a formatted quantity of non-volatile memory accessed by a host through a controller.

The main ideas

01

What the history preserves

01-01Support, storage limits and actual contents are distinct. Understand subsystem scope, persistence and possible omissions before treating the log as a complete trace.

02

The retrieval lifecycle

02-01Establish context → read header → retrieve chunks → compare generation → release. Separate newly logged events from the fixed set being retrieved.

context
The report selection and tracking state used by this retrieval; later events are excluded.
header
The leading descriptive structure containing the type, size, revision and related interpretation data.
03

Three layers of data

03-01The log header describes the report, the common event header describes one record, and ED contains type-specific data. Lengths and revisions belong to different layers.

ED
Event Data, the type-specific content after the common header and optional vendor information.
04

Build justified relationships

04-01Group health, time/reset, storage changes, sanitization, hardware and configuration. Combine target, action and result rather than inferring success from one name, percentage or timestamp.

05

Connecting Base and NVM

05-01Base provides the Namespace Change envelope; NVM specifies FLBAS/DPS. Vendor extensions complete the picture while unknown content remains bounded and preserved.

FLBAS
Formatted LBA Size, encoding a format index and metadata transfer mode, not a literal byte size.
DPS
End-to-end Data Protection Type Settings, selecting protection-information type and position.
NVM
Non-Volatile Memory, memory that retains data without power.

00.02.Assumes operating systems, computer organization and basic SSD concepts. Controllers A/B, namespace7 and numeric examples are illustrative, not assumed hardware configurations.

00.03.The Chinese tutorial develops the reasoning and field examples; the equivalent posts establish a global view and then provide a forward Spec route. Other references supply only fields needed to interpret these events.

Connecting the main ideas

00.04.Follow five questions: what can this device log, which report am I reading, where does each record begin, what does its payload mean, and what conclusion does the evidence support?

00.05.Use a lifecycle diagram for contexts, a byte-layout diagram for lengths, and time/target comparisons for events. Group related fields and explain shared structures once, with a distinct example for each source figure.

01 Distinguish history, current state and completeness

01.01.Persistent Event Log (PEL, LID 0Dh) retains significant NVM subsystem events across power cycles and resets. It is not a trace of every I/O or a guaranteed complete history: vendors define capacity, per-type limits, frequency suppression and eviction, and Sanitize may remove or modify records.

NVM subsystem
NVM subsystem, the NVMe system boundary containing controllers, ports, namespaces, and non-volatile storage resources.
I/O
Input/Output, the class of data operations performed on a namespace.
LID
Log Page Identifier: selects the type of log page to read.
PEL
Persistent Event Log, the history examined in this report.
Sources: Base 2.4 §5.2.13.1.14

Source: NVME-BASE-2.4, Rev. 2.4, §5.2.13.1.14, printed pages 244-245, PDF pages 270-271

02 Use a reporting context to retrieve one consistent report

One multipart retrieval: fix, verify, releaseArrows show host retrieval order. Reset or retention expiry can lose a context; changed GNUM calls for rereading. ACT3 reuse does not incorporate later events. Source: Base §5.2.13.1.14, Figure232.Check support and coordinate context useACT1 establish, or ACT3 establish/reuseRead header: TLL, GNUM, RCEACT0: read chunks from the fixed event setNew events are logged outside this contextACT0 reread header and compare GNUMChanged: reread; unchanged: finish checkingACT2 release; persistent history remains
Arrows show host retrieval order. Reset or retention expiry can lose a context; changed GNUM calls for rereading. ACT3 reuse does not incorporate later events. Source: Base §5.2.13.1.14, Figure232.
GNUM
Generation Number, compared before and after multipart retrieval.
Host
The system running the operating system and issuing NVMe commands.
RCE
Reporting Context Exists, indicating a context already present when processing began.

02.01.A reporting context fixes the event set for this report; later events are still logged but excluded from that context. ACT=1 establishes and reads, failing if a context exists; ACT=0 reads an existing context, failing if absent; ACT=2 releases and tolerates absence. Supported ACT=3 establishes or reuses a context and always returns the 512-byte header at offset zero.

reporting context
The event selection, locations and tracking information for one report, distinct from the underlying persistent history.
offset
A displacement from the specified origin, in bytes from zero unless stated otherwise.
ACT
Action, selecting PEL read, establish or release operations.
Sources: Base 2.4 §5.2.13.1.14

Source: NVME-BASE-2.4, Rev. 2.4, §5.2.13.1.14, printed pages 245-246,251, PDF pages 271-272,277

03 Walk from the header to each event boundary

One event: count VSI only onceIllustration: start512, EHL21, VSIL4, EL20. Widths are schematic, not proportional to byte counts. Positions are relative to the log origin. Source: Base Figure234.Header = EHL + 324 bytesVSI = VSIL4 bytesED = EL − VSIL16 bytes512 … 535536 … 539540 … 555Next record = 512 + 24 + 20 = 556
Illustration: start512, EHL21, VSIL4, EL20. Widths are schematic, not proportional to byte counts. Positions are relative to the log origin. Source: Base Figure234.
VSIL
Vendor Specific Information Length in bytes.
EHL
Event Header Length, excluding the first three bytes.
VSI
Vendor Specific Information, the optional addition in the common event format.
EL
Event Length, counting VSI and ED after the event header.

03.01.The log header occupies LHL+20 bytes and an event header occupies EHL+3 bytes. EL already includes the VSIL vendor-information bytes: total record size is EHL+3+EL and ED size is EL−VSIL. LREV describes the outer format; ET and ETR select the payload format.

LREV
Log Revision, the outer log and common event-header revision.
ETR
Event Type Revision, the type-specific payload revision.
LHL
Log Header Length, excluding the first20 bytes.
ET
Event Type, the record’s type code.
Sources: Base 2.4 §5.2.13.1.14

Source: NVME-BASE-2.4, Rev. 2.4, §5.2.13.1.14, printed pages 247-251, PDF pages 273-277

04 Interpret health snapshots, telemetry references and temperature events

Three events answer different questions
EventPreserved dataQuestion answered
01h SMART512-byte health snapshotHistorical health and counters
0Ch TelemetryFirst512-byte diagnostic headerWhich capture and which boundaries
0Dh ThermalThreshold code and relative differenceWhich crossing or thermal-control change
Telemetry blocks are absent, and a thermal event is not another full SMART snapshot. Sources: Base Figures237,254,255.
Telemetry
Diagnostic internal-state data; the event here preserves only its header.
snapshot
A copy captured at one time, distinct from later current state.

04.01.ET=01h stores a 512-byte SMART snapshot at intervals no greater than 24 power-on hours. ET=0Ch may record the first 512 bytes of newly created telemetry, not its complete diagnostic data. ET=0Dh records thermal-threshold events; OTMP is a Kelvin difference from a threshold, not an absolute temperature. These are historical observations.

Sources: Base 2.4 §5.2.13.1.14.2.1; 5.2.13.1.14.2.12; 5.2.13.1.14.2.13

Source: NVME-BASE-2.4, Rev. 2.4, §5.2.13.1.14.2.1; 5.2.13.1.14.2.12; 5.2.13.1.14.2.13, printed pages 252,264-266, PDF pages 278,290-292

05 Connect firmware, timestamps and reset records

05.01.ET02 is logged when Firmware Commit completes and does not by itself prove activation. ET04 records completed power-on/reset with the effective FREV and per-controller information. ET03 stores the previous timestamp in PTSTP and the new timestamp in the event header ETSTP. Timestamps may originate at reset, be host-set, or include periods when counting stopped.

controller
Controller, the entity that implements the NVMe interface, fetches commands, and reports completions.
ETSTP
Event Timestamp, the event time recorded in the common header.
Sources: Base 2.4 §5.2.13.1.14.2.2; 5.2.13.1.14.2.3; 5.2.13.1.14.2.4; 5.2.30.1.8

Source: NVME-BASE-2.4, Rev. 2.4, §5.2.13.1.14.2.2; 5.2.13.1.14.2.3; 5.2.13.1.14.2.4; 5.2.30.1.8, printed pages 252-254,470-471, PDF pages 278-280,496-497

06 Connect namespace changes to NVM format fields

The same value moves to a different offsetCreate uses host input and single Delete uses NVM Identify; both share these source offsets. Delete All reserves the fields. Sources: Base247; NVM112,123,134.Source byte26FLBAS = 12hEvent byte32FLBAS = 12hSource byte29DPS = 01hEvent byte33DPS = 01hFormat index2 · extended metadata · PI Type112h does not mean an 18-byte LBA
Create uses host input and single Delete uses NVM Identify; both share these source offsets. Delete All reserves the fields. Sources: Base247; NVM112,123,134.
metadata
Additional information stored with a logical block; it can contain protection information or serve other purposes.
PI
Protection Information used to check data integrity and associated information.

06.01.ET06 records successful Namespace Management commands. Base Figure247 defines the payload and field origins; NVM Figure112 specializes byte32 FLBAS and byte33 DPS: host-specified values for creation, Identify values for single-namespace deletion, and reserved fields for deletion of all namespaces.

Sources: NVM Command Set 1.3 §4.1.4.4

Source: NVME-NVM-CS-1.3, Rev. 1.3, §4.1.4.4, printed pages 76-77, PDF pages 76-77

07 Separate sanitize start, completion and media verification

Sanitize event names and what they establish
RecordEstablished factNot yet established
09h StartEntered processing; parameters and NSID savedOperation completed
0Eh Media VerificationEntered verification; no EDSuccessful completion or NSID in ED
0Ah Completion + SOS3Entered failure stateFFFFh proves success
0Ah Completion + SOS1This operation succeededNo data can ever be written afterward
This compares justified conclusions; it does not guarantee complete event pairs. Sources: Base §§5.2.13.1.14.2.9,.10,.14.
NSID
Namespace Identifier, a controller-visible numeric handle for a namespace; the identifier is not the namespace object itself.

07.01.ET09 records entry into sanitize processing; ET0A records entry into Idle or a failure state. Successful command completion is not completion of the long-running operation. ET0E marks entry into Media Verification with ETR=1 and EL=0, carrying no ED. Start/completion NSID identifies the target; FFFFFFFFh means the subsystem.

Sources: Base 2.4 §5.2.13.1.14.2.9; 5.2.13.1.14.2.10; 5.2.13.1.14.2.14

Source: NVME-BASE-2.4, Rev. 2.4, §5.2.13.1.14.2.9; 5.2.13.1.14.2.10; 5.2.13.1.14.2.14, printed pages 261-262,266, PDF pages 287-288,292

08 Select the hardware-error code before its additional format

08.01.In ET05, NSHEEC selects the hardware-error kind and thereby the AHEI layout and length. Codes01h–03h carry PCIe error information, 08h unexpected-power-loss information, and 0Bh controller-ready timeout information; some kinds have no AHEI. Vendors select supported subtypes, so one fixed layout cannot decode every ET05.

NSHEEC
NVM Subsystem Hardware Error Event Code, selecting an ET05 subtype.
AHEI
Additional Hardware Error Information, whose format depends on the error subtype.
PCIe
PCI Express, the transport and device interconnect used by an NVMe memory-based controller.
Sources: Base 2.4 §5.2.13.1.14.2.5

Source: NVME-BASE-2.4, Rev. 2.4, §5.2.13.1.14.2.5, printed pages 254-258, PDF pages 280-284

09 How feature events preserve commands and data

Set Feature ED: locate data using three parametersLayout-only example: DWC3, MBC8, LCCDW01. No particular FID is assumed to use these fields. Source: Base Figure253.SFEL · bytes0–30008000BhCDW10–12 · bytes4–153 × 4 = 12 bytesMBUF · bytes16–238 bytesCCDW0 · bytes24–274 bytesED = 4 + 12 + 8 + 4 = 28 bytes
Layout-only example: DWC3, MBC8, LCCDW01. No particular FID is assumed to use these fields. Source: Base Figure253.
SFEL
Set Feature Event Layout, locating command words, buffer data and completion DW0.
FID
Feature Identifier: selects the Feature to read or configure.

09.01.ET0B must be logged for successful value-changing Set Features when logging is supported; successful same-value requests may be logged. Figure252 O/P/NR describes logging requirements for a feature/controller type, not feature support. SFEL locates consecutive command Dwords, an optional data buffer and optional completion DW0.

P
Phase Tag, the toggling bit used by the host to decide whether a CQ slot contains a new completion.
Sources: Base 2.4 §5.2.13.1.14.2.11

Source: NVME-BASE-2.4, Rev. 2.4, §5.2.13.1.14.2.11, printed pages 262-264, PDF pages 288-290

10 Read identifier mappings and vendor extensions within their boundaries

10.01.ET10 records creation, deletion or entity changes of an Exported NVM Subsystem; OTYP determines whether EEID/UEID identify a namespace, controller, port or another object. ETDE ED contains vendor descriptors, each 6+VSEDL bytes and interpreted by VSEDT. A vendor event differs from the optional VSI attached to any event. ETDF payload formatting is reserved for TCG definition.

TCG
Trusted Computing Group, to which Base reserves the relevant security-event payload definition.
Sources: Base 2.4 §5.2.13.1.14.2.16; 5.2.13.1.14.2.17; 5.2.13.1.14.2.18

Source: NVME-BASE-2.4, Rev. 2.4, §5.2.13.1.14.2.16; 5.2.13.1.14.2.17; 5.2.13.1.14.2.18, printed pages 267-270, PDF pages 293-296

A forward route through the specification

R-1Frame the problem using the overview and examples, then follow PDF viewer page numbers forward. Finish the Base section and switch to NVM once. The Chinese tutorial explains necessary references without repeated page detours.

Page orderStart headingFocus and stop heading
R1 · Base PDF 270–2725.2.13.1.14Start at the section heading, after the preceding table tail. Explain retention/limits and the four ACT operations. Stop before Figure233.
R2 · Base PDF 273–277Figure233Walk from the log header to the event header, then ECRH and the type table. Use the scoped fields taught here. Stop before 5.2.13.1.14.2.1.
R3 · Base PDF 278–2845.2.13.1.14.2.1Cover SMART, firmware, time, reset and hardware; state what each establishes before reading its payload. Stop before 5.2.13.1.14.2.6.
R4 · Base PDF 284–2905.2.13.1.14.2.6Cover Namespace, Format, Sanitize, Set Feature and Telemetry. Introduce FLBAS/DPS here and complete their decoding in the final NVM stop. Stop before 5.2.13.1.14.2.13.
R5 · Base PDF 291–2965.2.13.1.14.2.13Finish thermal, verification, personality, entity mappings and vendor descriptors. Stop after the TCG paragraph, before the next log section. Stop before 5.2.13.1.15.
R6 · NVM PDF 76–774.1.4.4Switch documents once. Read the Persistent Event Log heading and Figure112 to finish FLBAS/DPS origins for Create, single Delete and Delete All. Stop before 4.1.4.5.
ECRH
Establish Context and Read Header, the capability for ACT3 and GNUM.
Open the complete Chinese tutorial and figure explanations →

Check your understanding

1. After successful ACT3 returns RCE=0, is ACT1 still needed?

12.01.No. RCE=0 describes absence before processing; ACT3 has established the context and returned the header. Continue with ACT0. ACT1 would now fail because a context exists.

Sources

Source: NVME-BASE-2.4, Rev. 2.4, §5.2.13.1.14, printed pages 245-246,251, PDF pages 271-272,277

2. With EHL21, VSIL4 and EL20, is the record 44 or 48 bytes?

12.02.44. EHL+3 is the 24-byte header; EL20 already includes four VSI bytes, leaving sixteen ED bytes. 48 double-counts VSI and misses the next record’s start.

Sources

Source: NVME-BASE-2.4, Rev. 2.4, §5.2.13.1.14, printed pages 247-251, PDF pages 273-277

3. Does a PEL telemetry header naming nine data blocks include those blocks?

12.03.No. ET0C copies only the first512 header bytes, preserving historical boundaries, reason and generation. It neither contains the full data nor guarantees the same capture remains available.

Sources

Source: NVME-BASE-2.4, Rev. 2.4, §5.2.13.1.14.2.1; 5.2.13.1.14.2.12; 5.2.13.1.14.2.13, printed pages 252,264-266, PDF pages 278,290-292

4. Does event byte32=12h imply an 18-byte LBA?

12.04.No. Valid FLBAS12h selects format index2 and extended metadata, not size18. First exclude Delete All, where the field is reserved; actual sizes come from the selected format definition.

Sources

Source: NVME-NVM-CS-1.3, Rev. 1.3, §4.1.4.4, printed pages 76-77, PDF pages 76-77

Source: NVME-NVM-CS-1.3, Rev. 1.3, §4.1.5.1; 4.1.6, printed pages 85-87,112-113, PDF pages 85-87,112-113

5. Does SPROG=FFFFh in a sanitize-completion event prove successful sanitization?

12.05.No. Read SOS: for example, 3 means failure. FFFFh also appears outside processing and during Media Verification; it is not a standalone success percentage.

Sources

Source: NVME-BASE-2.4, Rev. 2.4, §5.2.13.1.14.2.9; 5.2.13.1.14.2.10; 5.2.13.1.14.2.14, printed pages 261-262,266, PDF pages 287-288,292

Source: NVME-BASE-2.4, Rev. 2.4, §5.2.13.1.38, printed pages 314-316, PDF pages 340-342

6. Does absence of a feature event prove the host never changed that setting?

12.06.No. Check the feature’s logging policy and support first: it may be prohibited, optional or discouraged. Then consider eviction, frequency suppression and whether the current context predates the change.

Sources

Source: NVME-BASE-2.4, Rev. 2.4, §5.2.13.1.14.2.11, printed pages 262-264, PDF pages 288-290

Source: NVME-BASE-2.4, Rev. 2.4, §5.2.13.1.14, printed pages 244-245, PDF pages 270-271

Source: NVME-BASE-2.4, Rev. 2.4, §5.2.13.1.14, printed pages 245-246,251, PDF pages 271-272,277

Specification editions

NVM Express Base Specification, Revision 2.4

NVM Express NVM Command Set Specification, Revision 1.3

Jia-Chang

Jia-Chang

Human

Comments